LTR-2
| Datasheet: Enervent LTR-2 |
| Ducts | Ø 125 mm |
| Width | 972 mm |
| Height | 362 mm |
| Depth | 393 mm |
| Weight | 41 kg |
| Can also be installed in a cold space with extra insulation |
| Fan options: |
| eco (119 W) | -70 / +75 l/s |
| Air flow maximum: | -70 / +75 l/s | (exhaust/supply air flow) |
| House air volume: | ~ 0 - 388 m³ |
The LTR-2 is a small horizontal-style air handling unit equipped with the energy efficient rotating heat exchanger. The air flow range of the LTR-2 is up to 70 liters/sec at 125 Pa static duct pressure loss. This unit can be installed in an attic saving precious living space in small apartments and houses. When equipped with extra insulation, it can also be installed in a cold attic.
The unit is manufactured of galvanized sheet metal. It is equipped with efficient direct current fans and with F4/5 level panel filters. F7 class bag filters and an electric after heater (400 W or 800 W) are optional. The LTR-2 is available with both Enervent control system options; the cost-effective ECC control and the more versatile EDA control system.
Control options
 |
EDA Control
- An user-friendly digital control
- Cooling recovery
- Heating and cooling control
- Shortcuts for fan speeds and temperature control
- Calendar-based control possible
- Support for both AC and DC fans
- Remote management possible with the Freeway Gateway
|
 |
EC Control
- Digital control
- Four fan speeds
- Fireplace boost optional
- Supports only electrical heating
- No cooling control
|
Available models